Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Exhaust-gas operated pump
Gas compressor and gas pumping station operative
Gas pumping station operator
Gas station operator
Gas-compressor operative

Vertaling van "exhaust-gas operated pump " (Engels → Nederlands) :

TERMINOLOGIE
exhaust-gas operated pump

door uitlaatgassen aangedreven pomp


gas compressor and gas pumping station operative | gas-compressor operative | gas pumping station operator | gas station operator

operator gaspompstation | exploitatietechnicus gascompressie-installatie | operator gascompressie
IN-CONTEXT TRANSLATIONS
‘secondary air’ means the air introduced into the exhaust system by means of a pump or aspirator valve or other means that is intended to aid in the oxidation of HC and CO contained in the exhaust gas stream.

„secundaire lucht”: lucht die door middel van een pomp, aanzuigklep of ander systeem in het uitlaatsysteem wordt gebracht en die de oxidatie van koolwaterstoffen en CO in de uitlaatgassen moet bevorderen.


specific provisions to ensure the correct operation of NOx control measures; such provisions shall ensure that vehicles cannot be operated if the NOx control measures are inoperative due, for example, to lack of any required reagent, incorrect exhaust gas recirculation (EGR) flow or deactivation of EGR.

specifieke bepalingen om de correcte werking van de NOx-beheersingsmaatregelen te garanderen; dergelijke bepalingen zorgen ervoor dat voertuigen niet kunnen werken als de maatregelen ter beperking van NOx onwerkzaam zijn, bijvoorbeeld als gevolg van het ontbreken van een noodzakelijk reagens of een verkeerde of uitgeschakelde uitlaatgasrecirculatiestroom (EGR).


In addition, the manufacturer shall provide the approval authority with information on the operating strategy of the exhaust gas recirculation system (EGR), including its functioning at low temperatures.

De fabrikant verstrekt de goedkeuringsinstantie bovendien informatie over de werkingsstrategie van het uitlaatgasrecirculatiesysteem (EGR), inclusief de werking bij lage temperatuur.


2.2.1. Determination of the Diluted Exhaust Gas Flow PDP-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust is kept within ± 6 K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x273 / (101,3 x T) where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle V0 = volume of gas pumped per revolution under test conditions (m³/rev) NP = total revolutions of pump per test pB = atmospheric pressure in the test cell (kPa) p1 = press ...[+++]

Bepaling van de verdunde uitlaatgasstroom PDP-CVS-systeem De massastroom gedurende de cyclus wordt als volgt berekend, indien de temperatuur van het verdunde uitlaatgas gedurende de cyclus met behulp van een warmtewisselaar binnen ± 6 K wordt gehouden: M TOTW = 1,293 * V0 * NP * (pB - p1 ) * 273 / (101,3 * T) waarin: M TOTW = massa van het verdunde uitlaatgas op natte basis gedurende de cyclus; V0 = gasvolume dat onder testomstandigheden per omwenteling wordt gepompt (m³/omw); NP = totaal aantal omwentelingen van de pomp per test; PB = luchtdruk in de beproevingsruimte (kPa); p1 = drukvermindering t.o.v. de luchtdruk aan de pompinlaa ...[+++]


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
3. Where the fluorinated greenhouse gas charge for refrigeration, air conditioning or heat pump equipment is not indicated in the manufacturer’s technical specifications or on the label of that system, the operator shall ensure that it is determined by certified personnel.

3. Als de vulling met gefluoreerd broeikasgas van koel-, klimaatregelings- of warmtepompapparatuur niet in de technische specificaties van de fabrikant of op het etiket van het betrokken systeem is vermeld, zorgt de exploitant ervoor dat deze door een gekwalificeerde persoon wordt bepaald.


These criteria aim to limit the environmental impacts from manufacture, operation and end of life of electrically driven, gas driven or gas absorption heat pumps.

Deze criteria zijn gericht op de beperking van de milieueffecten van de fabricage, de werking en het einde van de levenscyclus van elektrische, gas- of gasabsorptiewarmtepompen.


In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) where NP,i = total revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ± 11K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x t x Kv x pA / T where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle t = cycle time (s) KV = cali ...[+++]

De momentane massa van het verdunde uitlaatgas wordt dan als volgt berekend: M TOTW ,i = 1,293 * V0 * NP,i * (pB - p1 ) * 273 / (101,3 x T) waarin: NP,i = totaal aantal omwentelingen van de pomp per tijdsinterval. CFV-CVS-systeem De massastroom gedurende de cyclus wordt als volgt berekend, indien de temperatuur van het verdunde uitlaatgas gedurende de cyclus met behulp van een warmtewisselaar binnen ± 11 K wordt gehouden: M TOTW = 1,293 * t * Kv * pA / T waarin: M TOTW = massa van het verdunde uitlaatgas op natte basis gedurende de cyclus; t = cyclusduur (s); K V = kalibreringscoëfficiënt van de kritische stroomventuri voor standaardom ...[+++]


At the completion of the test, the measurement of the exhaust gas mass flow rate, the diluted exhaust gas volume, the gas flow into the collecting bags and the particulate sample pump shall be stopped.

Na voltooiing van de test moeten de meting van de uitlaatgasmassastroom, de verdunde uitlaatgasvolumestroom, de gasstroom naar de verzamelzakken en de deeltjesbemonsteringspomp worden stopgezet.


A sample of the diluted exhaust gas is taken from the dilution tunnel DT of a partial flow or full flow dilution system through the particulate sampling probe PSP and the particulate transfer tube PTT by means of the sampling pump P. The sample is passed through the filter holders(s) FH that contain the particulate sampling filters.

Er wordt met behulp van de bemonsteringspomp P een monster van het verdunde uitlaatgas uit de tunnel DT van een partiële- of volledige-stroomverdunningssysteem genomen via de deeltjesbemonsteringssonde PSP en de deeltjesverbindingsleiding PTT. Het monster wordt door de filterhouder(s) FH geleid die de deeltjesbemonsteringsfilters bevat(ten).


The diluted exhaust gas flow rate is measured either with a positive displacement pump PDP or with a critical flow venturi CFV or with a sub-sonic venturi SSV.

De verdunde uitlaatgasstroom wordt gemeten met een verdringerpomp PDP, een kritische stroomventuri CFV of een subsonische venturi SSV.




Anderen hebben gezocht naar : exhaust-gas operated pump     gas pumping station operator     gas station operator     gas-compressor operative     


datacenter (1): www.wordscope.be (v4.0.br)

'exhaust-gas operated pump' ->

Date index: 2022-04-09
w