Back pressure regulator
Back pressure valve
Back-pressure valve
Check valve
Constant pressure valve
Dry back pressure valve
Evaporator pressure regulator
Two-temperature valve

Traduction de «dry back pressure valve » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
dry back pressure valve

intercepteur sec | soupape seche


back pressure regulator | back pressure valve | constant pressure valve | evaporator pressure regulator | two-temperature valve

régulateur de pression d'évaporation | robinet à pression minimale constante


back-pressure valve | check valve

clapet de non-retour | clapet de retenue | soupape de retenue


1.3.3. The valve shall open when the exhaust-gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 0,35 and 0,40 kPa.

1.3.3. La soupape s'ouvre lorsque la contre-pression des gaz d'échappement, mesurée à 100 mm au moins en aval de la bride d'entrée, atteint une valeur comprise entre 0,35 et 0,40 kPa.


The valve shall open when the exhaust-gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 0,35 and 0,40 kP a. It shall close when this pressure does not differ by more than 10 per cent from its stabilized value with the valve open.

La soupape doit s’ouvrir lorsque la contre-pression des gaz d’échappement, mesurée à 100 mm au moins en aval de la bride d’entrée, atteint une valeur comprise entre 0,35 et 0,40 kPa. Elle doit se refermer lorsque cette pression ne s’écarte pas de plus de 10 % de sa valeur stabilisée lorsqu’elle est ouverte.


The valve shall open when the exhaust gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 35 and 40 kP a. It shall close when this pressure does not differ by more than 10 % from its stabilized value with the valve opened.

La soupape doit s’ouvrir lorsque la contre-pression des gaz d’échappement, mesurée à 100 mm au moins en aval de la bride d’entrée, atteint une valeur comprise entre 35 et 40 kPa. Elle doit se fermer quand cette pression ne s’écarte pas de plus de 10 % de sa valeur stabilisée quand la soupape est ouverte.


2.3. All approved bottom-loading vehicles will carry an identification plate which specified the maximum permitted number of loading arms which may be operated simultaneously whilst ensuring that no vapours are released via the compartment P and V valves, when the maximum plant back pressure is 55 millibar as specified in 2.2.

2.3. Tous les véhicules homologués à chargement en source seront munis d'une plaque d'identification spécifiant le nombre maximal autorisé de bras de chargement qui peuvent être actionnés simultanément tout en évitant la fuite de vapeurs via les soupapes P et V des compartiments lorsque la contrepression maximale du système est de 55 millibars comme spécifié au point 2.2.


The valve must open when the exhaust-gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 0 735 and 0 740 bar.

L'ouverture de la soupape doit se produire lorsque la contrepression des gaz d'échappement, mesurée à 100 mm au moins en aval de la bride d'entrée, atteint une valeur comprise entre 0,35 et 0,40 bar.