Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Back pressure gauge
Cabin differential pressure gage
Cabin differential pressure gauge
Cabin differential pressure indicator
Discharge gauge
Head pressure gauge
High pressure gauge
Low pressure gauge
Suction gauge

Vertaling van "Pressure-gauge " (Engels → Frans) :

TERMINOLOGIE
discharge gauge | head pressure gauge | high pressure gauge

manomètre de refoulement


back pressure gauge | low pressure gauge | suction gauge

manomètre d'aspiration


cabin differential pressure gage | cabin differential pressure gauge | cabin differential pressure indicator

manomètre de pression différentielle de cabine | manomètre différentiel de cabine


A positive shut-off valve and a pressure gauge having a pressure range of not less than 1,5 times and not more than twice the test pressure shall be installed in the pressure supply piping and the accuracy of the gauge shall be 1 per cent of the pressure range.

Une vanne d’arrêt commandé et un manomètre ayant une plage de pressions d’au moins 1,5 fois et d’au plus 2 fois la pression d’épreuve doivent être montés sur la tuyauterie d’alimentation en pression et la précision du manomètre doit être de 1 % de la plage de pressions.


A positive shut-off valve and a pressure gauge having a pressure range of not less than 1,5 times nor more than 2 times the test pressure shall be installed in the pressure supply piping and the accuracy of the gauge shall be 1 per cent of the pressure range.

Une vanne d’arrêt commandé et un manomètre ayant une plage de pressions d’au moins 1,5 fois et d’au plus 2 fois la pression d’essai doivent être montés sur la tuyauterie d’alimentation en pression et la précision du manomètre doit être de 1 % de la plage de pressions.


4.2.2. The pressure supply system shall be equipped with a positive shut-off valve and a pressure gauge, having a pressure range of not less than 1,5 times nor more than 2 times the test pressure and the accuracy of the gauge shall be 1 per cent of the pressure range.

4.2.2. Le système d’alimentation en pression doit être équipé d’une vanne d’arrêt positive et d’un manomètre, ayant une plage de pressions d’au moins 1,5 fois et d’au plus 2 fois la pression d’épreuve et la précision du manomètre doit être de 1 % de la plage de pressions.


// Examination of the stability of the properties of pressure gauges // // The tests consist in subjecting pressure gauges to: // // (a) a pressure exceeding the upper limit of the measuring range by 25 % for 15 minutes; // // (b) 1 000 pulses produced by a pressure varying from 0 to 90-95 % of the upper limit of the measuring range; // // (c) 10 000 cycles of a pressure varying slowly from approximately 20 % to approximately 75 % of the upper limit of the measuring range at a frequency not exceeding 60 cycles per minute; // // (d) an ambient temperature of - 20 °C for six hours and a temperature of + 50 °C for six hours.

// Examen de stabilité des qualités des manomètres // // Les essais consistent à soumettre les manomètres à: // // a) une pression dépassant la limite supérieure de l'étendue de mesure de 25 %, pendant 15 minutes; // // b) 1 000 impulsions données par une pression variant de 0 à 90/95 % de la limite supérieure de l'étendue de mesure; // // c) 10 000 cycles d'une pression variant lentement d'environ 20 % à environ 75 % de la limite supérieure de l'étendue de mesure avec une fréquence ne dépassant pas 60 cycles par minute; // // d) une température ambiante de 20° C pendant 6 heures, et à une température ambiante de + 50 °C pendant 6 heu ...[+++]


- under heading No 90.24, instruments and apparatus for measuring, checking or automatically controlling the flow, depth, pressure or other variables of liquids or gases, or for automatically controlling temperature, (for example, pressure gauges, thermostats, level gauges, flow meters, heat meters, automatic oven-draught regulators), not being articles falling within heading No 90.14;

- à la position 90.24, les appareils et instruments pour la mesure, le contrôle ou la régulation des fluides gazeux ou liquides, ou pour le contrôle automatique des températures, tels que manomètres, thermostats, indicateurs de niveau, régulateurs de tirage, débitmètres, compteurs de chaleur, à l'exclusion des appareils et instruments du nº 90.14;




datacenter (1): www.wordscope.be (v4.0.br)

'Pressure-gauge' ->

Date index: 2025-07-30
w